>> system types
>> render protected systems and reinforcement
>> the insulant
>> the finish
>> beads & trims
>> fixing methods
>> fire performance

>> click here to view the
Case Study
|
|
Main System Types
 |
|
- Direct Applied Render Protected Systems (to Masonry and
Panel Backgrounds):
These systems use the basic components of an insulated render or
cladding system, insulant applied directly to the substrate, render
basecoat/s, reinforcement and finish (cementitious or synthetic)
|
 |
|
- Rail Supported, Render Protected Systems to Masonry and
Panel Backgrounds:
A mechanically fixed system supported by rails fixed to the substrate,
comprising insulant, render reinforcement and finish.
|
 |
|
- Rail Applied Ventilated Rainscreen Cladding Systems:
These systems use mechanically fixed steel or aluminium rails,
rock fibre slab insulation and performed cladding material to
present a 'screen' against weather.
|
Render Protected Systems & Reinforcement
- Traditional Render Systems
Thick render systems, up to 25mm thick comprise traditional density
pre-bagged basecoats and topcoats to comply with BS 5262. These systems
are normally used in combination with a metal lath carrier. They
are used widely in exposed areas and for high rise, or where high
impact resistance is required.
Suitable finishes include all mineral and synthetic finishes (see the
finish)
- Polymer Modified & Polymeric Render Systems
Thin render systems up to 15mm thick, using polymer modified, adhesive
renders applied in one or two coats using an alkali resistant woven
glass fibre mesh as reinforcement.
Suitable finishes include most mineral and all synthetic finishes.
- Register of Inca Systems
For comprehensive details of all available systems, please download
the following document:
Register of Systems
|
|